CFLPW - PCB-A-20 ISOOCTANE 1ML, AROCLOR 1248
- MSDS: CFLPW
- Manufacturer: SUPELCO INC
- Product Name: PCB-A-20 ISOOCTANE 1ML, AROCLOR 1248
- National Stock Number: 6630-00N043338
Product Identification
Product ID:PCB-A-20 ISOOCTANE 1ML, AROCLOR 1248
MSDS Date:05/25/1994
FSC:6630
NIIN:00N043338
Kit Part:Y
MSDS Number: CFLPW
Responsible Party
BELLEFONTE, PA 16823-0048
US
Emergency Phone: 814-359-3441
Info Phone: 814-359-3441
Cage: 54968
Contractor
Telephone: 314-771-5765/414-273-3850X5996
Cage: 54968
Ingredients
POLYCHLORINATED BIPHENYL (AROCLOR 1248); (AROCLOR 1248)
CAS: 12672-29-6
RTECS: TQ1358000
Fraction By Weight: 0.0001%
OSHA PEL N/K
ACGIH TLV: N/K
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
PENTANE, 1,2,4-TRIMETHYL-; (ISO-OCTANE) (CERCLA)
CAS: 540-81-1
RTECS: SA3320000
Fraction By Weight: 100%
OSHA PEL N/K
ACGIH TLV: N/K
Hazards
LD50 LC50 Mixture:SEE INGREDIENT 1
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: CONTAINS LOW CONCENTRATION(S)
OF MATERIAL(S) KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER.
SUCH CONCENTRATION(S) IS/ARE SUBSTANTIALLY BELOW OSHA-HCS
THRESHOLDS WHICH WOULD REQUIRE LISTING H EREIN AS A COMPONENT OF
THIS MIXTURE. HUMAN SUSPECT - CARCINOGEN.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYES: FLUSH WITH WATER FOR AT LEAST 15 MINUTES. SKIN: FLUSH
WITH LARGE VOLUMES OF WATER. INHAL: IMMEDIATELY MOVE TO FRESH AIR.
GIVE OXYGEN IF BREATHING IS LABORED. IF BREATHING STOPS, GIVE
ARTIFICIAL RESPIRATION. INGEST: NEVER GIVE ANYTHING BY MOUTH TO
UNCONSCIOUS PERSON. NEVER TRY TO MAKE AN UNCONSCIOUS PERSON VOMIT.
DO NOT INDUCE VOMITING.
Fire Fighting
Flash Point Method:CC
Flash Point:10F,-12C
Lower Limits:1.1%
Upper Limits:6.0%
Extinguishing Media:FOAM, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:CAN REACT VIGOROUSLY WITH REDUCING
MATERIALS.
Accidental Release
Spill Release Procedures:TAKE UP WITH ABSORBENT MATERIAL. VENTILATE
AREA.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE IN SEALED CONTAINER IN COOL, DRY
LOCATION. KEEP AWAY FROM HEAT. STORE IN DRY, WELL VENTILATED AREA.
KEEP AWAY FROM IGNITION SOURCES.
Other Precautions:AVOID EYE/SKIN CONT. AVOID BREATHING VAPS. THIS MATL
IS INTENDED FOR R&D USE ONLY & MAY NOT BE USED FOR DRUG,
HOUSEHOLD/OTHER PURPOSES. IT IS SUBJECT TO TSCA REGS @ CFR 40 PART
720.36 WHICH DEAL W/EXE MPTION OF CHEMS USED IN RESEARCH(SUPDAT)
Exposure Controls
Respiratory Protection:NIOSH APPROVED FACE MASK WITH ORGANIC VAPOR
CANISTER.
Ventilation:USE ONLY IN WELL VENTILATED AREA.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
OTHER PREC:& DEVELOPMENT FROM PMN (PREMANUFACTURE NOTIFICATION)
REQUIREMENTS. IN ADDITION, BURDEN OF SAFE USE OF MATL RESTS W/YOU
&, THEREFORE, IT SHOULD BE HANDLED ONLY BY QUALIFIED PERSONS
TRAINED I N LABORATORY PROCEDURES AND GOOD SAFETYPRACTICES.
Chemical Properties
Boiling Pt:B.P. Text:210F,99C
Melt/Freeze Pt:M.P/F.P Text:-177F,-116C
Vapor Pres:41
Vapor Density:3.90
Spec Gravity:0.690 (H*2O=1)
Evaporation Rate & Reference:>1 (ETHER =1)
Appearance and Odor:CLEAR COLORLESS LIQUID.
Percent Volatiles by Volume:100
Stability
Stability Indicator/Materials to Avoid:YES
REDUCING AGENTS.
Stability Condition to Avoid:NOT APPLICABLE.
Hazardous Decomposition Products:NOT APPLICABLE.
Disposal
Waste Disposal Methods:COMPLY WITH ALL APPLICABLE FEDERAL, STATE, OR
LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.